Overview of the error sources detected by the controller and the corresponding reactions
Error code Meaning TRIP Message Warning Off Code
CCr System error • - - - -
CE0 Communication error (AIF) 9 - 9 • C0126
CE1 Communication error at the process data input object
CAN-IN1 (time monitoring can be set under C0357/1)
9 - 9 • C0591
CE2 Communication error at the process data input object
CAN-IN2 (time monitoring can be set under C0357/2)
9 - 9 • C0592
CE3 Communication error at the process data input object
CAN-IN3 (time monitoring can be set under C0357/3)
9 - 9 • C0593
CE4 BUS-OFF state (many communication errors have occurred) 9 - 9 • C0595
EEr External monitoring • 9 9 9 C0581
H05, H07 Internal error • - - - -
H10 Sensor error - heatsink temperature • - 9 9
C0588
H11 Sensor error - internal temperature • - 9 9
LP1 Motor phase failure detection (function block must be
entered in C0465)
9 - 9 • C0597
LU Undervoltage - • - - -
Nmax Maximum speed exceeded (C0596) • - - - -
nErr Speed monitoring 9 9 9 • C0576
OC1 Short circuit • - - - -
OC2 Earth fault • - - - -
OC5 I x t overload • - - - -
OH Heatsink temperature 1 (max. permissible, fixed) • - - - -
OH3 Motor temperature 1 (max. permissible, fixed) • - - 9 C0583
OH4 Heatsink temperature 2 (adjustable; C0122) - - • 9 C0582
OH7 Motor temperature 2 (can be set; code: C0121) - - • 9 C0584
OH8 Motor temperature (fixed) via inputs T1/T2 9 - 9* • C0585
OU Overvoltage in the DC bus - • - - -
P01 Limit switch negative = LOW 9 - - - C1285/1
P02 Limit switch positive = LOW 9 - - - C1285/2
P03 Following error - digital frequency > C0255 9 - • 9 C0589
P04 Position limit exceeded in negative direction 9 - - - C1285/3
P05 Position limit exceeded in positive direction 9 - - - C1285/4
P06 No reference 9 - - - C1287/1
P07 Parameter set mode absolute 9 - - - C1291/1
P08 Actual offset out of range 9 - - - C1291/2
P09 Impermissible programming 9 - - - C1291/3
P12 Encoder range exceeded 9 - - - C1288/1
P13 Phase overflow • - 9 9 C0590
P14 1st following error POS > C1218/1 9 - 9 9 C1286/1
P15 2nd following error POS > C1218/2 9 - 9 • C1286/2
P16 Sync error 9 - 9 9 C1290/1
P17 TP control error 9 - 9 9 C1289/1
P18 Internal limitation 9 - • 9 C1289/2