Loading...
Function library
Monitorings
9.3.3 Monitoring functions
9-222
L
EDSVS9332S-D11 EN 3.0
Error code CodeOffWarningMessageTRIPMeaning
PEr Program error - - - -
PI Fault during initialisation - - - -
PR0 General fault in parameter sets - - - -
PR1 Fault in parameter set 1 - - - -
Sd2 Resolver error - 9* 9 C0586
Sd3 Encoder error at X9 PIN 8 9 - 9* C0587
Sd5 Encoder error at X6/1 X6/2 (C0034 = 1) 9 - 9 C0598
Sd6 Sensor error: motor temperature (X7 or X8) - 9 9 C0594
Sd7 Error in the absolute value encoder at X8 9 - - C0025
Sd8 Error in the sine / cosine encoder 9 - - C0580
default setting
9 possible
- not possible
9* possible, but the drive can be destroyed if the fault is not removed immediately.