Technical data
3.3 Rated data
3-5
L
EDSVS9332S-B EN 3.0
3.3.2 Types 9321 to 9324 with 200% overcurrent
Type EVS9321-ES EVS9322-ES EVS9323-ES EVS9324-ES
Order No. EVS9321-ES EVS9322-ES EVS9323-ES EVS9324-ES
Data for the operation on a mains: 3 AC/400 V / 50 Hz/60 Hz
Motor power (4-pole ASM)
P
r
[kW] 0.37 0.75 1.5 3.0
M
o
t
o
r
p
o
w
e
r
(
4
p
o
l
e
A
S
M
)
P
r
[hp] 0.5 1.0 2.0 4.0
Output power U, V, W (8 kHz) S
r8
[kVA] 1.0 1.7 2.7 4.8
Output current (8 kHz)
2)
I
r8
[A] 1.5 2.5 3.9 7.0
Output current (16 kHz)
2)
I
r16
[A] 1.1 1.8 2.9 5.2
Max. output current (8 kHz)
1)
I
max8
[A] 3.0 5.0 7.8 14.0
Max. output current (16 kHz)
1)
I
max16
[A] 2.2 3.6 5.8 10.4
Max. standstill current (8 kHz) I
08
[A] 3.0 5.0 7.8 14.0
Max. standstill current (16 kHz) I
016
[A] 2.2 3.6 5.8 10.4
Data for the operation on a mains: 3 AC/480 V / 50 Hz/60 Hz
Motor power (4-pole ASM)
P
r
[kW] 0.37 0.75 1.5 3.0
M
o
t
o
r
p
o
w
e
r
(
4
p
o
l
e
A
S
M
)
P
r
[hp] 0.5 1.0 2.0 4.0
Output power U, V, W (8 kHz) S
r8
[kVA] 1.2 2.1 3.2 5.8
Output current (8 kHz)
2)
I
r8
[A] 1.5 2.5 3.9 7.0
Output current (16 kHz)
2)
I
r16
[A] 1.1 1.8 2.9 5.2
Max. output current (8 kHz)
1)
I
max8
[A] 3.0 5.0 7.8 14.0
Max. output current (16 kHz)
1)
I
max16
[A] 2.2 3.6 5.8 10.4
Max. standstill current (8 kHz) I
08
[A] 3.0 5.0 7.8 14.0
Max. standstill current (16 kHz) I
016
[A] 2.2 3.6 5.8 10.4
1)
The currents apply to a periodical load cycle with 10 seconds overcurrent with the current mentioned here and
50 seconds base load with 44 % I
rx
Majority in indiv. cases Setting in C0022 Thermal
continuous current
Maximum current
phase
Recovery phase
Continuous power I
max
150 % I
rx
100 % I
rx
150 % I
rx
for 60 s 75 % I
rx
for 120 s
Peak power I
max
>150 % I
rx
70 % I
rx
200 % I
rx
for 10 s 44 % I
rx
for 50 s
2)
This output current Irx applies to a maximum current to be set under C022 which has not exceeded 150% of the
rated controller current (nameplate).
If the maximum current is higher than this value, the continuous current automatically decreases to 70% of the
original value.
Overcurrent diagram: 6-5
All other data: 3-4
Tip!
Yo u c a n s w i t c h t o I
max
> 150 % I
rx
only if the controller is inhibited.