277
To display the status for all PoE ports, click Monitor, PoE, Scheduling.
PoE Auto Checking Status
Use the Auto Checking Status to display the status for all PoE ports.
PATH
Monitor \ PoE \ Auto Checking
Figure 141: PoE Auto Checking Status
PARAMETERS
These parameters are displayed:
Port This is the logical port number for autochecking.
Ping Mode This shows the PoE autochecking status for the selected port.
IP Address This IP address is used to ping the PoE IP device connecting to the port.
Interval Number The Interval Number is the number of interval for IP checking. It takes
about 1 second to check each port, and about 9 seconds for one cycle interval.
Interval Number: = 1(9sec), 2(18sec), 3(27sec), 4(36sec), 6(54sec), 8(72sec), 12(108sec),
16(144sec).
Failure Action The Failure Action indicates the action will be taken when IP check fails
during the interval.
Reboot: To reboot the IP PoE device connecting to the port.
Nothing: To do nothing.
Retry Number The Retry Number indicates the number of retries of the IP check failures
before the failure action is taken.
Retry Number: 1 ~ 5. It starts counting the retry number after the first IP check fails.
Reboot Time The Reboot Time indicates the time duration of PoE OFF, before turning
PoE ON again.
Reboot Time[Second]: 3 ~ 120 seconds.