Loading...
Diagnostic information 2-107
7526
Go Back
Previous
Next
844.xx—Scanner Error—scan module output level error service check
845.xx—Scanner Failure service check
Scan module cable failure or SCC card failure. CCD channel failure.
Step Questions / actions Yes No
1 Check the flatbed lamp.
Is the lamp on brightly?
Go to step 2. Replace the flatbed lamp.
See “Flatbed CCD carrier
module removal” on
page 4-250.
2
Remove the left cover. See “Left cover
removal” on page 4-24.
Are the cables (A and B) securely connected?
Go to step 3. Reseat the flatbed CCD
cable.
3
Are the cables damaged? Replace the flatbed
scanner. See “Flatbed
scanner removal” on
page 4-255
Replace the flatbed CC
carrier module. See
“Flatbed CCD carrier
module removal” on
page 4-250.
Step Questions / actions Yes No
1 Check flatbed CCD cable (A). Remove the
flatbed with glass cover. See “Flatbed with
glass cover removal” on page 4-219.
Is the cable loose?
Reseat the flatbed CCD
cable.
Replace the flatbed
scanner. See “Flatbed
scanner removal” on
page 4-255.
2
Is the flatbed CCD cable damaged? Replace the flatbed CCD
cable.
Replace the scanner MDC
card. See “Scanner ICC
cable removal” on
page 4-260.