3-26 Service Manual
7526
Clear Log
Use Clear Log to remove the current information in the Event Log. This affects both the viewed log and the
printed log information.
1. Touch EVENT LOG from the Diagnostics Menu.
2. Touch Clear Log.
3. Touch YES to clear the Event Log or touch NO to exit the Clear Log menu.
If YES is selected, Deleting EVENT LOG displays on the screen.
Touch Back to return to EVENT LOG.
Scanner Tests
ASIC Test
This test initiates a scan of the scanner ASIC memory.
1. Touch SCANNER TESTS from the Diagnostics Menu.
2. Touch ASIC Test.
The results will be displayed as either ASIC Test Passed or ASIC Test Failed.
To clear the results, press .
Feed Test
The feed test scans and feeds continuously from either the ADF or the flatbed, depending on whether or not
paper is placed in the ADF.
1. Touch SCANNER TESTS in Diag Menu.
2. Touch Feed Test.
3. Use and to indicate the specific media size then touch Submit.
• If media is in the ADF, then ADF feed tests are performed.
• If no media is in the ADF or the media is exhausted, then the entire flatbed will be scanned
4. Running… Flatbed:0 ADF:0 displays and the number of successful scans is displayed by incrementing the
number beside the scan type.
If a failure occurs, Feed Test Failed Flatbed:xxxxx ADF:xxxxx. is displayed showing the number of failure
of each scan type.
5. Press to end the test and clear the messages.