Loading...
Diagnostic information 2-17
7526
Go Back
Previous
Next
83.xx Transfer Module
Life Warning
•Touch Continue to clear the message and continue printing.
Order a replacement transfer module. When print quality is reduced, install the new
transfer module using the instruction sheet that comes with the replacement transfer
module.
If the problem persists, replace the system board. See “System board removal” on
page 4-157.
83 Replace Transfer
Module
Replace the transfer module using the instruction sheet that comes with the replacement
transfer module. See “Transfer module removal” on page 4-180.
If the problem persists, replace the system board. See “System board removal” on
page 4-157.
83.41 Transfer Module
Missing
If you continuously get this error, then check the transfer module. Go to “920.03, 920.25—
Transfer Module Missing error service check” on page 2-112.
84 <color> PC Unit Life
Warning
•Touch Ignore to clear the message and continue printing.
Order the specified photoconductor unit. When print quality is reduced, install the new
specified photoconductor unit using the instruction sheet that comes with the replacement
specified photoconductor unit.
If the problem persists, replace the system board. See “System board removal” on
page 4-157.
Note: Make sure to reset the photoconductor unit counter(s).
84 Replace <color> PC
Unit
Replace the specified photoconductor unit using the instruction sheet that comes with the
replacement specified photoconductor unit. Navigate to Menu > Supplies menu >
Replace supplies.
If the problem persists, replace the system board. See “System board removal” on
page 4-157.
Note: Make sure to reset the photoconductor unit counter(s).