Error code Description Action
111.40 Wrong printhead installed. Go to
“Laser scanning unit (LSU) service
check” on page 134.
111.50 Open-loop printhead error, open-loop sweep
state.
111.51 Open-loop printhead error, open-loop sweep
state.
111.52 Open-loop printhead error, check prelim amp
state.
111.53 Open-loop printhead error, enable amp Kp state.
111.54 Closed-loop printhead error, amp Kp failed to
converge.
111.55 Closed-loop printhead error while waiting for amp
Kp to converge.
111.56 Closed-loop printhead error, amp Ki failed to
converge.
111.57 Closed-loop printhead error while waiting for amp
Ki to converge.
111.58 Closed-loop printhead error, load scan regs state.
111.59 Closed-loop printhead error, forward and reverse
capture times dier by too much.
111.60 Closed-loop printhead sweep error, check sweep
accuracy state.
Go to
“Laser scanning unit (LSU) service
check” on page 134.
111.61 Printhead drive control out of range due to an
external event beyond what the control is
designed to handle.
111.62 Closed-loop printhead error, o-resonant PI eort
state.
111.63 Timed out on POR sweep.
111.64 Attempted to exceed open loop drive limits.
111.65
111.66 Failed alignment of printhead.
111.67 Attempted to exceed open loop drive limits.
111.68 Too many fake HSYNCs while aligning printhead.
111.69 Attempted to exceed open loop drive limits.
7016
Diagnostic information