CablePartnumberMFDvariant
Straightpower
anddatacable
(suppliedwitha9x
anda12x)
R62379Allvariants
excludinga6xand
a7x
Rightangled
poweranddata
cable
R70029Allvariants
excludinga6xand
a7x
Cableextension
Powercablescanbeextendedifrequired.The
followingrestrictionsapplytoanyextensiontothe
powercable:
Cablemustbeofasuitablegaugeforthecircuit
load.
Eachunitshouldhaveitsowndedicatedpower
cablewiredbacktothedistributionpanel.
Totallength
(max)Supplyvoltage
Cablegauge
(AWG)
12V18
0–5m(0–16.4ft)
24V20
12V14 5–10m
(16.4–32.8ft)
24V18
12V12 10–15m
(32.8–49.2ft)
24V16
12V12 15–20m
(49.2–65.5ft)
24V14
Note:a6xanda7xMFDsare12Vonlyproducts.NEVER
connecta12Vonlyproducttoa24Vsystem.
Sharingabreaker
Wheremorethan1pieceofequipmentsharesa
breakeryoumustprovideprotectionfortheindividual
circuits.E.g.byconnectinganin-linefuseforeach
powercircuit.
D11637-2
2
4 4
1
3
+
-
1
Positive(+)bar
2
Negative(-)bar
3
Circuitbreaker
4Fuse
Wherepossible,connectindividualitemsof
equipmenttoindividualcircuitbreakers.Wherethis
isnotpossible,useindividualin-linefusestoprovide
thenecessaryprotection.
58aSeries/cSeries/eSeries