7. WEB Control Application
7-42
Line Speed Command Block Diagram
Speed Calculator
TensionDisable(P1 ~ P7)
0
Splicing Level(WEB_59)
1
-1
PID direction
)10_([%]
[%]
[%]
WEBDiameterMin
Diameter
SpeedLine
×
Diameter from Diameter calculation block
Speed reference
Line Speed from reference block
1
-1
Line Speed direction from reference block
PID output from PID block
1
-1
PID direction from
reference block
PID Type
WEB-44
If Line Speed is lower than WEB_45,
Output is WEB_45