13. Control Block Diagram
13-2
Setpoint setting(AI0:AI1)
Gain/Bias
AIO_03~10
AIO_11
LPF
LPF time
constana
AI1
AIO_01
AIO_02
-10 ~ 10V
0 ~ 10V
AI1 input
definition
AI1 input mode
Speed Ref
Proc PID Ref
Proc PID F/B
Draw Ref
Torque Ref
Flux Ref
Torque Bias
None
10 ~ 0V
0 ~ 20mA
Torque Limit
Ai1 Out Y2
= 200 %
Ai1 Out Y2
= 100 %
Ai1 Out Y2
= 50 %
Maximum
Speed
Speed
Voltage,
Current
Maximum
Speed / 2
5V,10mA 10V,20mA
Maximum
Speed
Speed
Voltage,
Current
Maximum
Speed / 2
5V,10mA 10V,20mA
Ai1 Out Y2
= 75 %
Ai1 Out Y1
=0%
Ai1 Out Y1
= 0 %
Ai1 Out Y1
= 25%
Ai1 Out Y1
= -10%
Gain, Bais setting
(10~0V, 20~0mA)
* AI2 ~ AI3 setting follows this
Sequence
20 ~ 0mA
10 ~ -10V
Line SPD Ref
Tension Ref
Dancer Ref
Taper Ref
Tension F/B
Diameter
Diam Preset
Ai1 Out Y2
=200 %
Ai1 Out Y2
= 100 %
Ai1 Out Y2
= 50 %
Maximum
Speed
Speed
Voltage
Maximum
Speed / 2
5V 10V
Ai1 In X1 = 0 %
Ai1 Out Y1 = 0 %
Gain, Bais setting
(10 ~ -10V)
Gain, Bais setting
(-10~10V, 0~20mA)
Ai1 Out Y2
=200 %
Ai1 Out Y2
= 100 %
Ai1 Out Y2
= 50 %
Maximum
Speed
Speed
Voltage,
Current
Maximum
Speed / 2
5V,10mA 10V,20mA
Maximu
m Speed
Speed
Voltage,
Current
Maximum
Speed / 2
5V,10mA 10V,20mA
Ai1 Out Y2
= 75 %
Ai1 In X1 = 0 %
Ai1 Out Y1 = 0 %
Ai1 Out Y1
= 0 %
Ai1 In X1
= 0%
Ai1 Out Y1
= 25 %
Ai1 Out Y1
=-10%
Ai1 In X1
= 0%

Table of Contents

Related product manuals