6. Function Description
6-10
1.10) Main Drive
Each inverter linked to system can be controlled separately. When this terminal is turned On, changing
operating speed reference, operating method, and torque limit is done via only Keypad without changing
the user-setting parameter value.
When ‘Main Drive’ terminal is turned On, Main Drive operation is available as shown below condition
.
z Inverter during stop: It is applied immediately.
z Inverter during operation: It is applied after stop.
The parameter value of FUN_01 Run/Stop Src, FUN_02 Spd Ref Sel, CON_28 Trq Lmt Src related with Operating
speed reference, Operating method, and Torque limit is not applied when ‘Main Drive’ terminal is turned On even
though parameter is changed via keypad or communication. It is applied when the terminal is turned Off during
stop.
The parameter value of CON_01 Control Mode is operated same as above parameter described.
The setting of Operating speed reference, Operating method and Torque limit is set as shown below.
Function "Main Drive" ON "Main Drive" OFF
Applied point of time
Operating
method
Keypad mode
Parameter value of
FUN_01 Run/Stop Src
Operating
Speed
reference
Keypad1 mode
Parameter value of
FUN_02 Spd Ref Sel
Torque Limit Kpd Kpd Kpd mode
Parameter value of
CON_28 Trq Lmt Src
Control Mode Speed mode
Parameter value of
CON_01 Control Mode
After inverter stop
1.11) 2nd Func (the 2
nd
function setting)
The iV5 inverter has the capability to control 2 motors independently. A second motor may be active by selecting one
terminal for this function and turn it ON. 2
nd
function is not displayed if the terminal is not defined for this or the defined
terminal is OFF.
Cross reference table for 1
st
function and& 2
nd
function
Parameter 2
nd
function 1
st
function
Acceleration time 2nd_09 2nd Acc time FUN_40 Acc. Time 1
Deceleration time 2nd_10 2nd Dec time FUN_41 Dec. time 1
Encoder-related
parameter
2nd_12 ~ 2nd_14 PAR_11 ~ PAR_15
Motor constants 2nd_15 ~ 2nd_26 PAR_16 ~ PAR 30
Electronic thermal level
for 1 min
2nd_32 2nd ETH 1min FUN_55 ETH 1min
Electronic thermal level
for continous
2nd_33 2nd ETH Cont FUN_56 ETH Cont