EasyManua.ls Logo

Luneau Technology Briot perception2 - Page 147

Default Icon
162 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance...Messages
5-146
LTO
0x19 Incompatible edger
configuration.
Automatic groove sub-fi-
nishing not allowed.
The job you have loaded calls
for Automatic groove sub-
finishing.
In the personalisation menus,
you have excluded this parame-
ter.
Therefore the edger cannot ac-
cept this job.
Confirm the message.
If you wish to load this job no-
netheless, change the personali-
sation of the pull-down menus.
Select Automatic groove sub-
finishing.
Load the job again.
0x1A Incompatible edger
configuration.
Basic groove sub-finishing
not allowed.
The job you have loaded calls
for Groove Curve sub-finishing.
In the personalisation menus,
you have excluded this parame-
ter.
Therefore the edger cannot ac-
cept this job.
Confirm the message.
If you wish to load this job no-
netheless, change the personali-
sation of the pull-down menus.
Select Groove curve sub-
finishing.
Load the job again.
0x1B Incompatible edger
configuration.
Groove distance (in mm)
sub-finishing not allowed.
The job you have loaded calls
for Groove distance (in mm)
sub-finishing.
In the personalisation menus,
you have excluded this parame-
ter.
Therefore the edger cannot ac-
cept this job.
Confirm the message.
If you wish to load this job no-
netheless, change the personali-
sation of the pull-down menus.
Select Front groove distance (in
mm) sub-finishing.
Load the job again.
0x1C Incompatible edger
configuration.
Percent groove sub-finishing
not allowed.
The job you have loaded calls
for Percent groove sub-fi-
nishing.
In the personalisation menus,
you have excluded this parame-
ter.
Therefore the edger cannot ac-
cept this job.
Confirm the message.
If you wish to load this job no-
netheless, change the personali-
sation of the pull-down menus.
Select Percent groove sub-
finishing.
Load the job again.
0x1D Incompatible edger
configuration.
Manual groove sub-finishing
not allowed.
The job you have loaded calls
for Manual groove sub-finishing.
In the personalisation menus,
you have excluded this parame-
ter.
Therefore the edger cannot ac-
cept this job.
Confirm the message.
If you wish to load this job no-
netheless, change the personali-
sation of the pull-down menus.
Select Manual groove sub-
finishing.
Load the job again.
0x1E Incompatible edger
configuration.
Drilling normal to rear face
not allowed.
The job you have loaded calls
for Drilling normal to rear face.
In the personalisation menus,
you have excluded this parame-
ter.
Therefore the edger cannot ac-
cept this job.
Confirm the message.
If you wish to load this job no-
netheless, change the personali-
sation of the pull-down menus.
Select Drilling normal to rear
face sub-finishing. Load the job
again.
0x1F Incompatible edger
configuration.
Drilling normal to front face
not allowed.
The job you have loaded calls
for Drilling normal to front face.
In the personalisation menus,
you have excluded this parame-
ter.
Theref
ore the edger cannot ac-
cept this job.
Confirm the message.
If you wish to load this job no-
netheless, change the personali-
sation of the pull-down menus.
Select Drilling normal to front
face sub-finishing.
Load the job again.
# Message title
Condition(s) for
display
Action(s)

Table of Contents