Maintenance...Messages
5-148
LTO
0x30 Do you want to save the
new personalisation?
At least one of the menu perso-
nalisation parameters has chan-
ged. The machine requests
confirmation of this
modification.
Confirm: the new
personalisation is registered.
No confirmation: the new
personalisation is not registered.
The previous personalisation is
retained.
Cancel: you return to the perso-
nalisation screen for the menu-
button concerned. Reselect the
elements you wish to display.
0x34 Groove too near front. The distance between the front
face of the lens and the external
edge of the groove is less than
0.2 mm.
Confirm the message.
Select Manual Groove sub-fi-
nishing.
Display the position of the groo-
ve on the control screen.
Reposition the groove.
0x35 Groove too far back. The distance between the rear
face of the lens and the internal
edge of the groove is less than
0.2 mm.
Confirm the message.
Select Manual Groove sub-fi-
nishing.
Display the position of the groo-
ve on the control screen.
Reposition the groove.
0x100 Requested job does not
exist.
You have called up a job number
but the corresponding job is not
on the server.
Load another number.
0x101 No response from server
within time limit.
You have tried to load a job but
the edger has not received a si-
gnal from the server.
Check that:
- The server is switched on.
- The OMA cord is correctly con-
nected to both terminals.
Then load the job again.
0x102 No server connected. The OMA cord is disconnected.
OR
The server is switched off.
Check that:
- The server is switched on.
- The OMA cord is correctly con-
nected to both terminals.
Then load the job again.
0x103 Corrupt OMA frame. The OMA frame sent by the ser-
ver displays a fault which pre-
vents reception.
Contact a Briot technician.
0x104 Invalid OMA frame. The OMA frame sent by the ser-
ver displays parameters which
the edger does not recognise.
Contact a Briot technician.
0x300 Touch screen not detected. When the edger is initialised, the
touch screen is not detected.
Contact a Briot technician.
0x404 Safety-Bevel or grooving im-
possible.
Safety-bevel and/or groove can-
not be made.
Confirm the message.
Select new parameters.
0x405 Holes removed (at least one
was unfeasible).
Do you want to continue?
The drilling plan includes at least
one hole positioned too close to
the block or too far from the
edge of the lens.
YES: the lens is edged but not
drilled. Then you can produce
the holes with a drill.
NO: the lens is not edged. Re-
move the lens from the edging
station.
# Message title
Condition(s) for
display
Action(s)