LX8000 version 0.96 April 2008
Page 76 of 85
9. Above below red by warning
10. 018°, 054°, 324° and 288° green and red flashing, obstacles in front
11. Check functionality of mode key, each short press will activate audio for a short time
After installation obligatory check functionality from 2 to 3 and 11.
9.1.4 Error messages
After Flarm failure has been detected, LX8000 will show this situation after booting and the
routine Flarm self test is not OK.
9.1.5 Flarm traffic information on moving map
All Flarm equipped gliders in range will be shown on moving map as small aircraft symbols,
whether or not they cause a collision warning or not. Each glider has own trace and
information of altitude and vario.
9.1.6 Flarm update procedure
Power on LX8000
Run Flarm tool and select communication port.
Connect LX8000 via PC cable with your PC
Go into password menu and enter password 42000
Following message will appear:
In the same time Flarm tool will detect Flarm. Please follow the instructions.