Malfunctions in driving mode
7.6 Troubleshooting
7 - 34 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
 7.6.9             Malfunctions on the suspension
 7.6.10             Malfunctions of the level adjustment system
Malfunction Cause Remedy
Suspension cannot be acti-
vated
Current speed above approx. 
5 km/h (3 mph) 
Slow down or stop the truck 
crane
Compressed air system 
insufficiently filled
à Building up supply pressure, 
p. 5 - 10 
Suspension cannot be 
switched on or off
Fuses F1/5, F2/1, F4/6, F5/4 
blown
Replace blown fuses; 
à p. 7 - 20 
Error symbol is displayed ECOS malfunction Read out error messages 
(
à p. 7 - 35) and notify 
Manitowoc Crane Care
Malfunction Cause Remedy
Level adjustment system not 
working
Suspension is switched off
à Switching the suspension on, 
p. 5 - 18 
Fuses F1/5, F2/1, F4/6, F5/4 
blown
Replace blown fuses; 
à p. 7 - 20 
Error symbol is displayed ECOS malfunction Read out error messages 
(
à p. 7 - 35) and notify 
Manitowoc Crane Care