Starting/switching off the engine – for crane operation
10.1 Starting the engine – from the crane cab
Operating Manual GMK6300L 3 112 xxx en 10 - 7
xx.xx.xxxx
10.1.4 Checks before starting the engine
At the hydraulic
tank
The valve on the hydraulic tank must be open before starting the engine.
• Check that the valve is open – lever (1)
parallel to the pipe.
• Open the closed valve.
Battery master
switch
You can only start the engine when the battery master switch is switched
on.
• Switch the battery master switch (1) on.
The battery master switch is switched on if
you are unable to pull off the selector handle.
s
S
Risk of damage to the hydraulic pumps!
You may only start the engine when the valve on the hydraulic tank is open!