Starting/switching off the engine – for crane operation
10.1 Starting the engine – from the crane cab
10 - 14 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
10.1.9 Checks after starting the engine
• Check the lamp (1) on the ECOS control unit immediately after starting the
engine.
The lamp (1) must go out approx. 10 seconds after starting the engine.
• Press the button (1) once. This opens the Warning submenu.
• If the symbol (2) is red, switch off the engine immediately.
• Check the oil level; à Maintenance Manual.
• Add oil if necessary. If the error message persists, refer to
Manitowoc Crane Care.
If other symbols are displayed in red in this menu;
à Warning submenu,
p. 11 - 110.
• Also check the following lamps on the side panel.
– If the lamp (2) does not go out or lights up while the engine is running,
switch the engine off and look for the cause.
– If the lamp (1) does not go out or lights up while the engine is running,
there is a malfunction in the flame start system.
à Malfunctions on the engine, p. 7 - 27
More information can be found in the
Monitoring submenu; Ã p. 10 - 15.
S
Risk of damage to the engine!
If the lamp (1) does not go out after approx. 10 seconds, perform the follow-
ing inspection and, if necessary, turn off the engine immediately.
Running the engine when the oil pressure is too low can damage it.