Page #966 background image
Malfunctions during crane operation
14.6 Hydraulic emergency operation
14 - 66 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
Emergency supply
When using an emergency supply, the con-
nections (1) feed a transformer (2) that is con-
nected to the hydraulic system of the other
crane;
à Emergency supply of another crane,
p. 14 - 76.
14.6.2 Connecting/disconnecting hoses
•
Turn off the engines for driving and crane operations.
Establishing
connections
The hoses are assigned according to the various diameters.
On the carrier
• Attach the transformer (3) to the super-
structure.
• Connect the hoses (2) to the connections (1).
S
Risk of damage to the hoses!
Lay the hoses in such a manner that they can be moved freely, so as to pre-
vent them being crushed or torn or becoming caught during subsequent
crane movements.