Malfunctions during crane operation
14.4 Finding and eliminating malfunctions
Operating Manual GMK6300L 3 112 xxx en 14 - 25
xx.xx.xxxx
 14.4.13             Malfunctions of the outriggers
Malfunction Cause Remedy
Outrigger cylinders and 
beams can neither be 
extended nor retracted and 
the inclination indicator does 
not work
Driver's cab: Fuses A3F3, 
A3F13, A3F14 blown
Replace blown fuse; 
à p. 7 - 20.
When operating with the 
hand-held control 
Driver's cab: Fuse A2F3 blown Replace blown fuse; 
à p. 7 - 20.
When operating from the 
crane cab 
Hand-held control connected 
to the superstructure or a 
bridging plug not inserted
Disconnect hand-held control 
or insert bridging plug; 
à p. 12 - 21.
When operating from the 
control units
Display fields switched off. Switch on display fields; 
à p. 12 - 31
Hand-held control connected 
to the superstructure or a 
bridging plug not inserted
Disconnect hand-held control 
or insert bridging plug; 
à p. 12 - 21
None of the specified causes 
apply 
Solenoid valves not working Manitowoc Crane Care 
Report it