Crane operation
11.2 Operation of the rated capacity limiter
Operating Manual GMK6300L 3 112 xxx en 11 - 41
xx.xx.xxxx
RCL override – symbol (A)
The status display (1) is active.
The following operating elements can be used
to override the RCL:
Status display
The status display informs people in the danger area of the truck crane:
– About the current degree of utilisation,
– In case of an RCL shutdown or early warning,
– When the RCL has been overridden.
The warning will be visual and, in part,
audible.
s
2 Key-operated RCL override switch
3 Key-operated rigging switch
4 Raise switch
1 Loudspeaker (warning signal)
2 Lamp, green
3 Lamp, yellow
4 Lamp, red