Malfunctions during crane operation
14.4 Finding and eliminating malfunctions
14 - 20 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
Waiting
The symbol usually disappears shortly after switching on the ignition.
If the symbol does not go out or is displayed while operating the crane,
this may be due to an RCL shutdown or blown F1/2 fuse. Contact
Manitowoc Crane Care if none of these are the cause.
Telescope status divergence
ECOS has detected a difference between the displayed and the current
telescope status. Enter the current telescope status;
à p. 14 - 57.
Emergency program access
The telescoping mechanism can only be operated with the emergency
programme;
à p. 14 - 45.
Emergency program
The
Telescoping emergency programme is open; Ã p. 14 - 45.
Inactive
Contact Manitowoc Crane Care if this status is still displayed after
repeatedly switching on the ignition.