7-MAINTENANCE
Every400hours
Hydraulicoillters
Thisprocedureisvalidforboththereturnlter(1)and
thecasedrainlter(2).
1.Removetheboltsandwashersattachingtheltercap.
Removethelterelementfromthelterhousing.
2.Replacetheelementwithanewelement.Besureto
reinstallallgaskets.IfgasketsorO-ringsaredeterio-
rated,replacewithnewparts.
3.Replacethelterassemblyintothehousing,being
carefultolineituptoproperlyseatthelterassembly
inthehousing.
4.Placetheholdingspringonthehubofthecap.Make
suretoreinstalltheO-ringseal.Reinstallthecapand
tightenthenuts,beingsurethespringandO-ringare
properlyseatedsothesuctionltersealstothefaceof
thelterhousing.
RAIL17SP00755AA1
RAIL14SP01015BA2
ItemDescription
1Filtercap
2
O-Ring
3
Mainreturnlterelement
4Hydraulicoilreservoir
5
Breatherlterelement(insidecap)
6
Casedrainlterelement
7
O-Ring
8
Cover
7-84