Warning / Error Messages
5-17
1
1
1
1
5
Troubleshooting
Message Cause Solution
USB device initialization failure.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears
again, contact your local distributor to call
for service.
Occurrence of a time out error on a
USB device.
An excessive load was applied to the X
motor.
An excessive load was applied to the Y
motor.
An error due to an excessive current of
the X motor was detected.
An error due to an excessive current of
the Y motor was detected.
An error was detected in the take-up
tension bar at media set check when
starting printing.
• Check the media set status, and solve
the problem.
An error was detected in the feeding
tension bar at media set check when
starting printing.
• Check the media set status, and solve
the problem.
An error occurred in the take-up status
of the take-up unit.
• Check that the media can be taken up to
the take-up unit.
• Check that the paper core taking up the
media does not run idle.
An error occurred in the feeding status
of the feeding unit.
• Check that the media can be taken up to
the feeding unit.
• Check that the media does not run idle.
The take-up cover opened during print-
ing.
• Close the take-up cover.
The feeding cover opened during print-
ing.
• Close the feeding cover.
The take-up limit sensor was detected
during printing.
• Lower the tension bar or move it to the
waiting position.
The feeding limit sensor was detected
during printing.
• Lower the tension bar or move it to the
waiting position.
The tension bar is in the upper position
during printing.
• Lower the tension bar.
An error occurred in the cutter encoder.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
An error occurred in the station position.
Time to replace the post cure lamp has
come.
• For replaceing the lamp, refer to P.4-34
“About time to replace lamp”.
The media jam occurs. • Remove the media and reset it.