6
8.23.2 Remove the EFCS Flowmeter Monitoring Board .......................................... 8-21
8.24 Disassemble the EFCS Flowmeter FRU (O2/N2O/Air) ............................................. 8-21
8.24.1 Prepare for Disassembly................................................................................. 8-21
8.24.2 Remove the EFCS Flowmeter FRU (O2/N2O/Air) ....................................... 8-21
8.25 Disassemble the EFCS Flowmeter Flow Sensors ....................................................... 8-22
8.25.1 Prepare for Disassembly................................................................................. 8-22
8.25.2 Remove the EFCS Flowmeter Flow Sensors ................................................. 8-22
8.26 Disassemble the N2O, Air, and O2 Cylinder Yoke Assemblies .................................. 8-23
8.26.1 Prepare for Disassembly................................................................................. 8-23
8.26.2 Remove the N2O, Air, and O2 Cylinder Yoke Assemblies ............................ 8-24
8.27 Disassemble the Sensor Adapter Board PCBA ........................................................... 8-24
8.27.1 Prepare for Disassembly................................................................................. 8-24
8.27.2 Remove the Sensor Adapter Board PCBA ..................................................... 8-25
8.28 Disassemble the High-Flow O2 Supply Assembly or Auxiliary O2/Air Assembly .... 8-25
8.28.1 Prepare for Disassembly................................................................................. 8-25
8.28.2 Remove the High-Flow O2 Supply Assembly or Auxiliary O2/Air Assembly8-26
8.29 Disassemble the System Switch Assembly ................................................................. 8-26
8.29.1 Prepare for Disassembly................................................................................. 8-26
8.29.2 Remove the System Switch Assembly ........................................................... 8-27
8.30 Disassemble the High-Flow O2 Therapy Flowmeter or Auxiliary Output Flowmeter
Assembly ............................................................................................................................. 8-27
8.30.1 Prepare for Disassembly................................................................................. 8-27
8.30.2 Remove the High-Flow O2 Therapy Flowmeter or Auxiliary Output Flowmeter
Assembly ................................................................................................................... 8-28
8.31 Disassemble the Upper-Half Drawer Assembly .......................................................... 8-28
8.31.1 Prepare for Disassembly................................................................................. 8-28
8.31.2 Remove the Upper-Middle Drawer Assembly ............................................... 8-28
8.32 Disassemble the Lower Drawer Assembly .................................................................. 8-29
8.32.1 Prepare for Disassembly................................................................................. 8-29
8.32.2 Remove the Lower Drawer Assembly ............................................................ 8-29
8.33 Disassemble the CO2 Locking Assembly ................................................................... 8-30
8.33.1 Prepare for Disassembly................................................................................. 8-30
8.33.2 Remove the CO2 Locking Assembly ............................................................. 8-30
8.34 Disassemble the AGSS Assembly ............................................................................... 8-31
8.34.1 Prepare for Disassembly................................................................................. 8-31
8.34.2 Remove the AGSS Assembly ......................................................................... 8-31
8.35 Disassemble the Module Rack Assembly ................................................................... 8-32
8.35.1 Prepare for Disassembly................................................................................. 8-32
8.35.2 Remove the Module Rack Assembly ............................................................. 8-32
8.36 Disassemble the Battery Box Assembly ...................................................................... 8-33
8.36.1 Prepare for Disassembly................................................................................. 8-33
8.36.2 Remove the Battery Box Assembly................................................................ 8-33
8.37 Disassemble the Anesthesia Calculation Pipeline Assembly ...................................... 8-34
8.37.1 Prepare for Disassembly................................................................................. 8-34
8.37.2 Remove the Anesthesia Calculation Pipeline Assembly ................................ 8-34
8.38 Disassemble the Drive Gas Assembly ......................................................................... 8-34
8.38.1 Prepare for Disassembly................................................................................. 8-34
8.38.2 Remove the Drive Gas Assembly ................................................................... 8-35
8.39 Disassemble the ACGO Assembly .............................................................................. 8-35
8.39.1 Prepare for Disassembly................................................................................. 8-35
8.39.2 Remove the ACGO Assembly ........................................................................ 8-35
8.40 Disassemble the O2 Cell Calibration Valve Assembly ................................................ 8-36
8.40.1 Prepare for Disassembly................................................................................. 8-36

Table of Contents

Other manuals for Mindray A9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray A9 and is the answer not in the manual?

Mindray A9 Specifications

General IconGeneral
TypeAnesthesia Workstation
Integrated Gas AnalysisYes
Backup BatteryYes
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 55°C
Battery TypeLithium-ion
Ventilation ModesVolume Control, Pressure Control, SIMV, Manual Ventilation
DisplayTouchscreen
Patient MonitoringECG, SpO2, NIBP, EtCO2, Temperature
ConnectivityEthernet, USB
PortabilityMobile (with wheels)
Battery LifeMinimum 90 minutes (typical)
AltitudeUp to 3000 meters
Power Supply100-240 VAC, 50/60 Hz
Charging TimeApproximately 4 hours
StorageInternal storage for patient data and system logs
Supported LanguagesMultiple languages
CertificationsCE, FDA