EasyManuals Logo

Mindray A9 Service Manual

Mindray A9
424 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
2-57
No. Description No. Description
1.1
Filter
12.1
Filter
1.2
Check Valve
12.2
Normally-Closed Switch Valve
1.3
Pressure Switch
12.3
Check Valve
1.4
Pressure Relief Valve
12.4
Proportional Valve
1.5
Pressure Regulating Valve
12.5
Flow Sensor
1.6
Cylinder Pressure Gauge
12.6
Filter
1.7
Electronic Pressure Sensor of Cylinder
12.7
2/3 Switch-Over Valve
1.8
Pressure Regulating Valve of Cylinder
12.8
Check Valve
1.9
Check Valve of Cylinder
12.9
Filter
1.12
Electronic Pressure Sensor of Pipeline
12.10
2/3 Switch-Over Valve
2.1
Filter
12.11
Check Valve
2.2
Electronic Pressure Sensor of Pipeline
12.12
Proportional Valve
2.3
Pressure Relief Valve
12.13
Flow Sensor
2.4
Check Valve
12.14
Flow Sensor
2.5
Pressure Regulating Valve
15.1
Internal AG
2.6
Cylinder Pressure Gauge
15.2
2/3 Switch-Over Valve
2.7
Electronic Pressure Sensor of Cylinder
15.3
2/3 Switch-Over Valve
2.8
Pressure Regulating Valve of Cylinder
15.4
Self-sealing Sampling Tube
2.9
Check Valve
15.5
External AG
3.1
Filter
16.1
Pressure Sensor
3.2
Electronic Pressure Sensor of Pipeline
16.2
2/3 Switch-Over Valve
3.3
Pressure Relief Valve
17.1
Flow Restrictor
3.4
Check Valve
17.2
ACGO Switch
3.5
Cylinder Pressure Gauge
17.3
11kPa (112 cmH
2
O) Pressure Relief
Valve
3.6
Electronic Pressure Sensor of Cylinder
17.4
ACGO Port
3.7
Pressure Regulating Valve of Cylinder
18.1
Check Valve
3.8
Check Valve
18.2
Airway Pressure Gauge
4.1
Overfill Protector
18.3
O2 Sensor
4.2
Negative Pressure Gauge
18.4
Differential Pressure Gauge of
Inspiration
4.3
Negative Pressure Regulating Switch
18.5
2/3 Switch-Over Valve
4.4
Mode Selector Switch
18.6
2/3 Switch-Over Valve

Table of Contents

Other manuals for Mindray A9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray A9 and is the answer not in the manual?

Mindray A9 Specifications

General IconGeneral
TypeAnesthesia Workstation
Integrated Gas AnalysisYes
Backup BatteryYes
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 55°C
Battery TypeLithium-ion
Ventilation ModesVolume Control, Pressure Control, SIMV, Manual Ventilation
DisplayTouchscreen
Patient MonitoringECG, SpO2, NIBP, EtCO2, Temperature
ConnectivityEthernet, USB
PortabilityMobile (with wheels)
Battery LifeMinimum 90 minutes (typical)
AltitudeUp to 3000 meters
Power Supply100-240 VAC, 50/60 Hz
Charging TimeApproximately 4 hours
StorageInternal storage for patient data and system logs
Supported LanguagesMultiple languages
CertificationsCE, FDA