15-341 15-341
15.3.5. Reset screen
The information (about battery, grease and belt) for Maintenance Forecast kept in the controller can be reset.
Figure 15-17 Reset
Table 15-5 Description about each reset
replacement
It is used when an alarm urging to replace
the batteries (C7500, C7510 or C7520)
occurs and the batteries have been replaced.
Be sure to reset the remaining battery time
after a battery has been replaced.
replenishment
When an alarm urging to perform periodic
inspection and grease replenishment (alarm
numbers in the 7530s) occurs, replenish the
grease and reset the replenished axis.
Axes are reset in units of joint
axes. Multiple joint axes can be
reset at the same time.
exchange
When an alarm urging to perform periodic
inspection and to replace the belt when it is
damaged (alarm numbers in the 7540s)
occurs, replace the belt and reset the axis for
which the belt is replaced.
Axes are reset in units of joint
axes. Multiple joint axes can be
reset at the same time.
These reset operations can be executed using the teaching box. See the following section for further details.