50
2 COMMON PARAMETERS
2.1 Parameters Used by the Motion CPU
*1 MELSEC iQ-R Motion Controller Programming Manual (Positioning Control)
Motion
control
parameter
Axis setting
parameter
Fixed parameter Set the fixed data based on the
mechanical system, etc. of the controlled
axis.
*1
Home position
return data
Set the data required for the home
position return.
JOG operation data Set the data to perform the JOG
operation.
External signal
parameter
Set the external signals (upper stroke limit
(FLS), lower stroke limit (RLS), stop
(STOP), and proximity dog or speed/
position switching (DOG/CHANGE)) used
for each axis.
Expansion
parameter
Set when the following functions are used.
• Individual monitoring of positive and
negative direction torque limit values
• Change the acceleration/deceleration
time when changing speed
• Set the servo motor maximum speed.
• When performing positioning control in
the absolute data method in degrees,
specify the positioning direction.
Speed-torque
control data
Set when the speed-torque control is
performed.
Optional data
monitor
Set the type of the monitored data and the
storage device when the servo amplifier
status, etc. is monitored.
Page 175
Optional data
monitor setting
Pressure control
data
Set when performing pressure control that
uses a profile.
*1
Override data Set when using the override function.
Vibration
suppression
command filter data
Set when using vibration suppression
command filter function.
Servo parameter Parameters for the servo amplifier and
sensing module are set based on the
specifications for the servo amplifier, servo
motor, and sensing module.
Parameter block Set the data for acceleration/deceleration
control, etc. used for each positioning
processing.
Synchronous
control
parameter
Input axis
parameter
Set the input axis used for advanced
synchronous control.
*2
Synchronous
parameter
Set the synchronous parameters for the
output axis used for advanced
synchronous control.
Multiple CPU
advanced
synchronous
control setting
Set the master CPU and slave CPU for
performing Multiple CPU advanced
synchronous control.
Machine
control
parameter
Machine common
parameter
Set the common parameters and point
blocks used for machine control.
*3
Machine parameter Set the parameters for performing
machine control.
G-code
control
parameter
G-code control
system parameter
*4
Set the parameters used on a line for each
G-code control line.
*5
G-code control axis
parameter
*4
Set the parameters for each axis in each
G-code control line.
G-code control
work parameter
*4
Set the parameters for working in G-code
control.
Parameter item Parameter input timing Details Reference
At ON/reset of
Multiple CPU
system power
supply
At STOP to
RUN/test
mode request