WARNING
• A crushing hazard exists between the nozzle and mold melt inlet during
carriage forward motion.
• A possible shearing hazard exists between the edge of the injection
guard and the injection housing during injection.
• The open feed port could present a hazard to a nger or a hand
inserted during operation of the machine.
• The electric servo motors could overheat presenting a hot surface which
could cause burns to someone touching it.
• The barrel, barrel head, nozzle, heater bands and mold components are
hot surfaces which could result in burns.
• Keep ammable liquids or dust away from the hot surfaces as they
could ignite.
• Follow good housekeeping procedures and keep oors clean to prevent
slips, trips and falls due to spilled material on the work oor.
• Apply engineering controls or hearing conservation programs as
necessary to control noise.
• When doing any work on the machine that requires moving and lifting
the machine, ensure that lifting equipment (eyebolts, fork lift truck,
cranes, etc.) will have sucient capacity to handle mold, auxiliary
injection unit or hot runner weight.
• Connect all lifting devices and support the machine using a crane of
adequate capacity before commencing work. Failure to support the
machine can result in severe injury or death.
• Mold cable from the controller to the mold must be removed before
servicing the mold.
Operational Hazards - continued
3-6
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
SAFETY
MT Controller User Manual