EasyManua.ls Logo

Motorola AP-6511 - Page 192

Motorola AP-6511
434 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motorola Solutions AP-6511 Access Point System Reference Guide
6-58
5. Refer to the Calibration Assignment field to define whether Smart RF Calibration and radio grouping
is conducted by floor or building. Both options are disabled by default.
6. Select OK to update the Smart RF Basic Configuration settings for this policy. Select Reset to revert to
the last saved configuration.
7. Select Channel and Power.
Use the Channel and Power screen to refine Smart RF power settings over both the 5 and 2.4 GHz radio
bands and select channel settings in respect to the device channel usage.
Coverage Hole
Recovery
Select the radio button to enable Coverage Hole Recovery when a radio
coverage hole is detected within the Smart RF supported radio coverage
area. When coverage hole is detected, Smart RF first determines the
power increase needed based on the signal to noise ratio for a client as
seen by the Access Point radio. If a client’s signal to noise value is above
the threshold, the transmit power is increased until the signal to noise rate
falls below the threshold. Coverage Hole Recovery is enabled by default
when Custom is selected as the Sensitivity option.
Neighbor Recovery Select the radio button to enable Neighbor Recovery when a failed radio is
detected within the Smart RF supported radio coverage area. Smart RF can
provide automatic recovery by instructing neighboring APs to increase their
transmit power to compensate for the coverage loss. Neighbor recovery is
enabled by default when Custom is selected as the Sensitivity option.