3.1 Installation environment
3.1.1 Installation environmental conditions for installation
Note
Do not open the front cover during printing.
If the front cover is opened, printing will be interrupted.
Printing restarts if you close the front cover. However, you are not guaranteed
to have high print quality.
Be sure to read and understand the safety warnings before handling the printer.
Floor strength of the installation place More than 2940 Pa (300 kg/m²)
Power specifications
Power supply AC 90 V - 120 V
Frequency range 50/60Hz
Power capacity 10A or more
Environmental
conditions
Operative condition
Temperature: 20°C to 32°C
Humidity: 40% to 60%, No condensation
Guaranteed range of
printing accuracy
Temperature: 20°C to 32°C
Humidity: 40% to 60%
Change rate
Temperature: Within 2°C per hour
Humidity: withing 5% per hour
Archiving
environment
Temperature: -20°C to 60°C
Humidity: 20% to 80%
no condensation
Note
Concerning temperature and humidity, avoid:
Places where temperature or humidity may rapidly change, even though within the
required conditions.
Places that receive direct sunlight, increased illumination or direct air, for example
from an air conditioner.
To keep the temperature and humidity constant, install this product in a
location where the air condition is adjustable.