EasyManua.ls Logo

NEC Aspire Series - Page 122

NEC Aspire Series
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
10-03 : PCB Setup
112 Networking
For SLIU Unit
For COIU Unit
For DIOPU Unit
For TLIU Unit
Physical Port Number 01-16
Item
No.
Item Input Data Default
01 Logical Port Number Through Software 3.07: 0-256
From Software 4.0E+: 0-384
0
02 Not used
03 Transmit Gain Level (S-Level) 1-63 (-15.5 +15.5dB) 32 (0dB)
04 Receive Gain Level (R-Level) 1-63 (-15.5 +15.5dB) 32 (0dB)
Physical Port Number 01-08
Item
No.
Item Input Data Default
01 Logical Port Number 0-200 0
Physical Port Number 01-08
Item
No.
Item Input Data Default
01 LD/OPX assignment 0 = LD Trunk
1 = OPX Trunk
0
02 Logical Port Number 0 = For LD Trunk 0-200
1 = For OPX Through Software 3.07:
0-256
From Software 4.0E+:
0-384
0
Physical Port Number 01-08
Item
No.
Item Input Data Default
01 Logical Port Number 0-200 0
02 2/4Wire 0 = 2Wire
1 = 4Wire
1