Programming
10-03 : PCB Setup
Networking 113
For BRIU Unit
ISDN Line Number 01-08
Item
No.
Item Input Data Default
01 ISDN Line Mode 0 = Not set
1 = T-Bus
2 = S-Bus
Options 3-5 determines the cloc
k source
for the networked connection.
3 = Network Mode (Leased Line)
Telco sends the clock to the Master System
Telco sends the clock to the Slave System
4 = Network Mode (Interconnected Line)
Master System sends the clock to the Telco (or direct
connection without telco) which then sends the clock
to the Slave System
5 = Network Mode (Interconnected Line, Fixed layer 1=NT)
Master System sends the clock to the Telco
Slave System sends the clock to the Telco
6 = S-Point (Leased Line)
1
02 Logical Port Number
(see Note 1)
0 = Net set
1 = For T-Bus (1-200)
2 = For S-Bus (Through Software 3.07: 0-256
From Software 4.0E+: 0-384)
0
03 Connection Type 0 = Point-to-Multipoint (not available for Networking)
1 = Point-to-Point
0
04 Layer 3 Timer Type (see Note 2) 1-5 1
05 CLIP Information Announcement
Based on this setting, the system will
include a “Presentation Allowed” (1)
or “Presentation Restricted” (0) in the
Setup message to allow or deny the
Calling Party Number. Program
15-01-04 must also be set to a ‘1’ if
this option is enabled.
0 = Disable
1 = Enable
1
06 Connection Bus Mode (S-point only) 0 = Extended Passive Bus
1 = Short Passive Bus
0
07 S-point DID digits 0-4 0
08 Dial sending Mode 0 = Enblock sending
1 = Overlap sending
1
09 Dial Information Element
(Only for Overlap Sending Mode)
0 = Keypad Facility
1 = Called Party Number
0
10 Master/Slave System (NW mode only) 0 = Slave System
1 = Master System
0