• When using fractional PRI, the unit comes up as zero ports until PRG 10-03-06 is set to the
4/8/12/16/20/24(auto), and then reset.
• If fractional PRI has the number of ports changed, the Trunk Port number might change if they
become split or fit into an empty gap of trunk ports.
• If using a CSU/DSU, PRG 10-03-13 must be set to 0. If not using a CSU/DSU, PRG 10-03-13 must
be set to 1~7 or anything other than 0.
• Restrictions for Calling Party Name:
The SL1100 supports receiving the name from the Network in supported formats only and cannot
send the Calling Name. Refer to Table 1-48 Restrictions for Calling Party Names on page 1-461.
Table 1-48 Restrictions for Calling Party Names
Protocols Name Delivery Formats
NI-2 Facility Information Elements
4ESS (AT&T Custom) Not Supported
AT&T 5ESS Lucent Custom Facility Information Element
DMS-100 (Custom) * Display Information Element *
DMS-100 (National; ISDN) ** Facility Information Element **
* Nortel Specification NIX-A211-1
** Nortel Specification NIS-A233-1
• CO Line Service is not supported.
ISDN - PRI cannot be configured for CO Emulation
ISSUE 2.0 SL1100
Features and Specifications Manual 1-461
I