Figure 1-38 Intuition Setup Page 2 - Extension Setting
Table 1-58 Extension (Terminal) Type on page 1-589 shows type of terminals supported at the Setup
Page 2.
Table 1-58 Extension (Terminal) Type
Type Input Range Required System Data
Digital handsets 0-72 PRG 10-03-01 (ESI): Terminal Type
Changed to: MLT
PRG 10-03-02 (ESI): Logical Port
Changed to: Logical Port Number
MLT is installed per 8 ports base.
So if 9 MLT ports are required 2 MLT related packages need to be instal-
led, port 10-16 is setup as unused MLT handsets.
(PRG 10-03 (ESI)-01 Terminal Type "No Setting")
SLT handsets 0-60 PRG 10-03-01 (SLI): Logical Port
Changed to: Logical Port Number
PRG 10-03-05 (SLI): Select Port Type
Changed to: SLT
SLT is installed per 4 or 8 ports base.
DSS Console 0-12 PRG 10-03-01 (ESI): Terminal Type
Changed to: DSS
PRG 10-03-02 (ESI): Logical Port
Changed to: Logical Port Number
NEC Doorphones 6 PRG 10-03-01 (SLI): Logical Port
Changed to: Logical Port Number
PRG 10-03-05 (SLI): Select Port Type
Changed to: DoorPhone
When you click "Next" and If you receive the similar message you received in page 1. Like in case of Page
1 please re-enter the number so that it won't exceed the MAX.
Below is example where Terminals exceeds the MAX number.
ISSUE 2.0 SL1100
Features and Specifications Manual 1-589
P