Power Failure Transfer
Description
Power Failure Transfer ensures that a customer has access to the Central Office network during a
power outage. The CO/PBX tip and ring are automatically transferred to a correspond Single Line
Terminal.
Conditions
The Single Line Terminals that are installed must provide a dialing signal accepted by the outside
exchange (Dial Pulse or Dual Tone Multifrequency).
Single Line Terminals and outside lines connected during power failure are fixed one-to-one.
System features cannot be activated from Single Line Terminal when Power Failure Transfer is in
operation.
When power is restored to the system the call in progress on Power Failure Transfer is maintained.
Refer to the SL1100 System Hardware Manual for the PFT Connections.
Power Failure phone need to be connected to Power Failure (PF) port on COIDB unit. A total of 9
Power Failure phones can be connected.
Default Settings
None
System Availability
Terminals
Single Line Terminal
Required Component(s)
COIDB-B1