Guide to Feature Programming
Program Num-
ber
Program Name Default
11-12-08 Service Code Setup (for Service Access) - Barge-In 710
11-16-02 One-Digit Service Code Setup - Barge-In not assigned
15-07-01 Programmable Function Keys Refer to Programming Manual.
20-06-01 Class of Service for Extensions Extension 101 is Class 15 and other Ex-
tension are Class 1
20-13-10 Class of Service Options (Supplementary Service) - Barge-
In Monitor
COS 01~15 = 0
20-13-15 Class of Service Options (Supplementary Service) - Barge-
In, Initiate
COS 01~15 = 0
20-13-16 Class of Service Options (Supplementary Service) - Barge-
In, Receive
COS 01~15 = 0
20-13-17 Class of Service Options (Supplementary Service) - Barge-
In Tone/Display (Intrusion Tone)
COS 01~15 = 1
20-13-32 Class of Service Options (Supplementary Service) - Multi-
ple Barge-Ins
COS 01~15 = 0
20-14-11 Class of Service Options for DISA - DISA/Tie Trunk Barge-
In
COS 01~15 = 0
20-18-07 Service Tone Timers - Intrusion Tone Repeat Time 0 (seconds)
21-01-03 System Options for Outgoing Calls - Trunk Interdigit Time
(External)
5 (seconds)
Operation
To Barge-In after calling a busy extension:
The time in PRG 21-01-03 must expire before you can Barge-In.
SL1100 ISSUE 2.0
1-70
Barge-In