GS108T Smart Switch Software Administration Manual
3-10 Managing System Settings
v1.0, May 2007
.
2. Primary Server: Define the RADIUS Primary Server authentication fields.
a. Host IP Addresses: Specify the IP address of the primary RADIUS server.
b. Authentication Port: Specify the UDP port number of the EAPOL control frame. The
default UDP port number is 1812, but other numbers can be used if the RADIUS server
can recognize them.
c. Number of Retries: Specify the number of times the switch sends the RADIUS request to
the server before giving up.
d. Time out for Reply: Specify the number of seconds the switch waits for the RADIUS
server to respond before resending the request.
e. Dead Time: Specify the number of minutes a RADIUS server, that is not responding to
authentication requests is to be skipped, thus avoiding the wait for the request to timeout
before trying the backup configured server.
f. Key String: Specify the string used by the RADIUS server as a password to identify
EAPOL control frames.
g. Usage Type: Select the usage of the radius server. The possible field values are:
Login: The Radius server is used for logging into switch.
Figure 3-9

Table of Contents

Other manuals for NETGEAR ProSafe GS108

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSafe GS108 and is the answer not in the manual?

NETGEAR ProSafe GS108 Specifications

General IconGeneral
MAC address table8000 entries
Maximum data transfer rate1 Gbit/s
Full duplexYes
Networking standardsIEEE 802.3ab, IEEE 802.3i, IEEE 802.3u
Copper ethernet cabling technology1000BASE-T, 100BASE-TX, 10BASE-T
Latency20 μs
Dimensions (WxDxH)235.5 x 100.8 x 27 mm
Power requirements5 V @ 2.8 A DC
Networking featuresEthernet, Fast Ethernet, Gigabit Ethernet
Switch typeUnmanaged
Basic switching RJ-45 Ethernet ports quantity8
Noise level0 dB
Mean time between failures (MTBF)91.500 h
Power consumption (typical)14 W
SafetyUL (UL 1950), CUL, C-Tick
LED indicatorsLink, Power
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)10 - 95 %
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Weight760 g