2. The Port Authentication Page contains the following fields:
ID: Displays a list of interfaces on which port-based authentication is enabled.
User Name: Displays the supplicant user name.
Admin Port Control: Displays the current port authorization state.
ReAuthenticate Now: Forces reauthentication of all existing clients.
Enable Periodic Reauthentication: Permits immediate port reauthentication. The
possible field values are:
Enable: Enables immediate port reauthentication. This is the default value.
Disable: Disables port reauthentication.
Reauthentication Period: Displays the time span (in seconds) in which the selected port
is reauthenticated. The field default is 3,600 seconds.
Authenticator State: Displays the current authenticator state.
Quiet Period: Displays the number of seconds that the device remains in the quiet state
following a failed authentication exchange. The possible field range is 0-65,535. The field
default is 60 seconds.
Figure 4-53

Table of Contents

Other manuals for NETGEAR ProSafe GS108

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSafe GS108 and is the answer not in the manual?

NETGEAR ProSafe GS108 Specifications

General IconGeneral
MAC address table8000 entries
Maximum data transfer rate1 Gbit/s
Full duplexYes
Networking standardsIEEE 802.3ab, IEEE 802.3i, IEEE 802.3u
Copper ethernet cabling technology1000BASE-T, 100BASE-TX, 10BASE-T
Latency20 μs
Dimensions (WxDxH)235.5 x 100.8 x 27 mm
Power requirements5 V @ 2.8 A DC
Networking featuresEthernet, Fast Ethernet, Gigabit Ethernet
Switch typeUnmanaged
Basic switching RJ-45 Ethernet ports quantity8
Noise level0 dB
Mean time between failures (MTBF)91.500 h
Power consumption (typical)14 W
SafetyUL (UL 1950), CUL, C-Tick
LED indicatorsLink, Power
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)10 - 95 %
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Weight760 g