Service ManualY100250-4 4-19
4.4.1.1 PRINTING PHOTOSENSOR CALIBRATION VALUES
Printing photosensor calibration values iis useful as reference between one calibration and the next.
Proceed as follows for alignment calibration:
1. Power on the printer with its cover open and while holding down the three buttons on the console.
2. Wait for the audible signal to sound indicating that the printer has switched to the calibration and
adjustment phase, then close the printer cover.
3. Press the STATION 1 button.
4. Press the LOCAL button.
5. When reset is completed, insert an A4 sheet of paper.
6. The sheet is inserted, printed and automatically expelled. The printer automatically switches to the
next calibration phase.