Service ManualY100250-4 4-27
Form length measurement is necessary for a rapid handling of a savings book magnetic stripe. By
selecting the "STRIPE HANDLING: FAST" set-up option, the value provided by the form measurement
procedure will be used to determine the position of the magnetic stripe and to position the stripe above
the magnetic head without needing to further measure the length of the savings book. This entails
greater time saving during savings book management. For this feature to work correctly the same
savings books measured must be used.
Proceed as follows to make this calibration:
1. Power on the printer with its cover open and while holding down the three buttons on the console.
2. Wait for the audible signal indicating that the printer has switched into the calibration and adjustment
mode.
3. Press the Local button and wait for the completion of machine reset.
4. Insert an A4 sheet of paper into the front insertion slot and then press Station 1. The sheet will be
inserted and expelled automatically.
5. If necessary, repeat step 5.
6. Press Local twice to permanently store the form length value measured and to automatically switch
to the next calibration.