235
Pulse Outputs Section 5-2
Origin Search Examples
Operation Connect a Servo Driver and execute an origin search based on the Servomo-
tor's built-in encoder phase-Z signal and a Origin Proximity Input Signal.
Conditions Operating mode: 1
(Uses the Servomotor encoder's phase-Z signal as the Origin Input Sig-
nal.)
Origin search operation setting: 0
(Sets reverse mode 1. Reverses direction when the limit input signal is
input in the origin search direction.)
Origin detection method: 0
(Reads the Origin Input Signal after the Origin Input Signal goes
OFFONOFF.)
Origin search direction: 0 (CW direction)
System Configuration
Instructions Used ORG(889)
CW limit
detection
sensor
Origin
Proximity
Input sensor
Workpiece
CCW limit
detection
sensor
Servomotor
Encoder
Servomotor Driver
Pulse output from built-in
outputs OUT0
0.00: Servomotor encoder's
phase-Z input; Origin input
0.10: Origin proximity input sensor
0.00: CW limit detection sensor
0.01: CCW limit detection sensor

Table of Contents