717
PLC Setup Appendix G
Operation Adjustment Settings
3 In-position range 0: 1 0: 1 When power is turned
ON
426 00 to 15 0000 hex
1 0001 hex
: :
65,535 FFFF hex
4 Min. output value 0: 1 0: 1 When power is turned
ON
427 00 to 15 0000 hex
1 0001 hex
: :
65,535 FFFF hex
5 Max. output value 0: 2,000,000 0: 2,000,000 When power is turned
ON
429, 428 00 to 15 00000000
hex
1 00000001
hex
: :
4,294,967,295 FFFFFFFF
hex
6 Error counter overflow
detection value
0: 10,000 0: 10,000 When power is turned
ON
430 00 to 15 0000 hex
1 0001 hex
: :
32,767 7FFF hex
7 Error counter alarm
detection value
0: 10,000 0: 10,000 When power is turned
ON
431 00 to 15 0000 hex
1 0001 hex
: :
32,767 7FFF hex
8 Error counter cycle 0: 3 (4-ms incre-
ments)
0: 3 (4-ms incre-
ments)
When power is turned
ON
417 00 to 07 00 hex
1 (4-ms incre-
ments)
01 hex
: :
255 (4-ms incre-
ments)
FF hex
9 Power Supply Freq. for
One Motor Revolution
per Sec.
0 (0.1-Hz incre-
ments)
0 (0.1-Hz incre-
ments)
When power is turned
ON
438 00 to 15 0000 hex
: :
65,535 Hz (0.1-Hz
increments)
FFFF hex
10 Number of Encoder
Pulses for One Motor
Revolution
0 0 When power is turned
ON
439 00 to 15 0000 hex
: :
65,535 FFFF hex
Name Default Settings When setting is read
by CPU Unit
Internal
address
Bits Settings
1 Limit output during
acceleration and con-
stant speed
Do not use Use When power is turned
ON
432 08 to 11 0 hex
Do not use 1 hex
2 Limit output during
deceleration and when
stopped
Do not use Use When power is turned
ON
432 12 to 15 0 hex
Do not use 1 hex
3 Output coefficient dur-
ing acceleration and
constant speed
0: 6 (0.01 incre-
ments)
0: 6 (0.01 incre-
ments)
When power is turned
ON
433 08 to 15 0 hex
1 (0.01 increments) 1 hex
: :
255 (0.01 incre-
ments)
FF hex
Name Default Settings When setting is read
by CPU Unit
Internal
address
Bits Settings