OMRON PART 1: CX-Programmer
CX-Programmer_Page (xxxiii)
Version 3.3 Upgrade Information
The following tables outline the changes that have been made from version 3.2 to version 3.3 of the CX-
Programmer.
• CJ1M-CPU11/21 Support Added
Previous version (version 3.2) New version (version 3.3)
The CJ1M-CPU11/21 was not
supported.
The CJ1M-CPU11/21 is supported.
To use the CX-Programmer for the CJ1M-CPU11, set the Device Type to the CJ1M and
the CPU Type to the CPU12. To use the CX-Programmer for the CJ1M-CPU21, set the
Device Type to the CJ1M and the CPU Type to the CPU22.
Creating a CX-Programmer Project for the CJ1M-CPU11/21
1. On the initial CX-Programmer display, select File – New and then set the Device Type to the CJ1M in
the Change PLC Dialog Box.
2. Click the Settings Button by the Device Type Field and set the CPU Type in the Device Type
Settings Dialog Box as shown below.
● CJ1M-CPU11: Set CPU12.
● CJ1M-CPU21: Set CPU22.
Setting Table
CPU Unit Model
Item
CJ1M-CPU11 CJ1M-CPU21
Device Type Set CJ1M.
CX-Programmer
Ver. 3.3
CPU Type Set CPU12. Set CPU22.
There are some restrictions in using the CJ1M-CPU11/21 with the new version of CX-Programmer (version 3.3). These
restrictions will be eliminated in the next version.