EasyManua.ls Logo

Omron CX-PROGRAMMER V9 - Page 72

Omron CX-PROGRAMMER V9
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OMRON PART 1: CX-Programmer
CX-Programmer_Page (xxxviii)
1a
1b
4
1a
2
2
3
2
1a
3
1a
3
4
1b
Master node
Slave node
(4) Participating nodes
(1) Area and Start Word
(3) Each Node, Received
and Sent
(2) Master, Common
Send Words
(Same as (3).)
(Same as (3).)
(Same as (3).)
Features of Chain Type 1:N Allocation
Data communications are 1:1 between the master node and slave nodes.
All slave nodes receive part of the data sent by the master node (1a in figure).
The master node receives all data sent by the slaves. The data sizes are fixe
for all nodes.
Each slave nodes receives data from the previous node and then sends dat
a
to the next node. Data is thus passed in ascending order of the node
s
participating in the data link.
One area is selected from the bit-access areas (e.g., CIO Area) or
word-access areas (e.g., DM Area).
Data link areas are allocated in ascending order of node addresses.
Data link participation can be specified for each node.
5. Click the Write Button to transfer the automatic data link setting.
Adding Nodes while Data Links Are Running
Previous version (version 3.1) New version (version 3.2)
Nodes can be added while data links are running if both the following Units/Boards and
Repeater Units (CS1W-RPT01) are used.
Controller Link Units
CS1W-CLK21-V1
Controller Support Boards
3G8F7-CLK21-V1 (-EV1)
CS1W-CLK12-V1 3G8F7-CLK12-V1 (-EV1)
CS1W-CLK52-V1 3G8F7-CLK52-V1 (-EV1)
Applicable
models:
CJ1W-CLK21-V1
Data link tables could not be
downloaded when data link
were running.
Note: Refer to the Controller Link Operation Manual for the procedure to add nodes and
details on changing data link tables while data links are running.
Up to 62 Nodes for Wired Controller Link Units
Previous version (version 3.1) New version (version 3.2)
A maximum of 62 nodes can now be used with Wired Controller Link Units.
CS1W-CLK21-V1
CJ1W-CLK21-V1
Applicable
models:
3G8F7-CLK21-V1 (-EV1)
Only a maximum of 32 nodes
could be used with Wired
Controller Link Units.
Note: A CS1W-RPT01 Repeater Unit must be purchased separately to use 62 Controller
Link Units. Refer to the Controller Link Operation Manual for details.
Displaying Data Link Table Information for Data Link Table
Verification
Previous version (version 3.1) New version (version 3.2)
Data link table verification
results were displayed in a
simple list in an Error List
Dialog Box.
When inconsistencies are detected in data link
verification, the number of inconsistent (failed)
nodes is displayed, and both the data link
settings within the selected PLC and those
with the inconsistencies indicated between
pointed parentheses (< >). (The size of the
dialog box can be changed.) Also, if reading is
not possible for verification, the reasons are
displayed.
The results can be pasted as text after clicking
a Copy Button.
100Base-TX for Ethernet Units
Previous version (version 3.1) New version (version 3.2)
Only 10Base-T and 10Base-5 were
supported in Unit settings (CPU Bus Unit
setups).
100Base-TX is also supported for Ethernet Unit in the Unit settings (CPU Bus
Unit setups).
Applicable models: CS1W-ETN21, CJ1W-ETN21

Table of Contents

Related product manuals