1.2 Receiving Group Features
44 Feature Guide
• If a Log-in/Log-out button and a G-DN button are created for the same group, the G-DN button will also
indicate the Log-in/Log-out status of the group (→ 1.18.3 LED Indication).
• Wrap-up Button
Any flexible button can be customized as the Wrap-up button. It shows the current status as follows:
• Group Call Waiting cannot be used simultaneously with Wrap-up. This is because when an extension
user completes a call with Call Waiting, the extension starts to ring immediately—the user is not given
any Wrap-up time. Call Waiting must be turned off on each extension that wants to use Wrap-up
feature.
• When a portable station (PS) in Wireless XDP Parallel Mode completes a call, neither the PS nor its
wired telephone can have Wrap-up time. (→ 1.20.3 Wireless XDP Parallel Mode)
• Automatic Log-out
An extension may be logged-out from a group automatically after the preprogrammed number of calls
go unanswered. This allows extensions to be logged-out automatically in the event users leave their
desks and forget to log out.
The number of consecutive unanswered calls before Automatic Log-out is applied can be programmed
for each ICD group. If an extension is a member of more than one ICD group, all calls unanswered by
the extension are tallied. Once an extension has been automatically logged out, the user can log back
in manually.
Automatic Log-out does not apply to extensions in an ICD group using Ring distribution.
• Log-in/Log-out Monitor
The supervisor extension can monitor and control the Log-in/Log-out status of group members. (→
1.2.2.7 Supervisory Feature)
• Log-in/Log-out Information on SMDR
Log-in/Log-out information can be logged by Station Message Detail Recording (SMDR). (→ 1.21.1
Station Message Detail Recording (SMDR))
Feature Guide References
1.18.2 Flexible Buttons
1.2.2.2 Group Call Distribution
User Manual References
1.8.1 Log-in/Log-out, Wrap-up
All groups Log-in/Log-out button is
pressed. All groups the
user belongs to are logged-
in to/logged-out from.
must be entered when
creating the Log-in/Log-out
button.
When
logged-out
When
logged-in
Light pattern Status
Slow red flashing Wrap-up
Red on Not Ready
Off Ready
Log-in/Log-out
Button Type
Usage Programming
Light Pattern
Red on Off