Value Range Max. 64 characters
Default Value panasonic
SSH_ACCESS_DISABLE
Value Format Boolean
Description Specifies whether to disable SSH access.
Value Range
• Y/Yes (Enable SSH)
• N/No (Disable SSH)
Default Value
Y
Web User Interface Reference Enable SSH (Page 193)
5.6 Telephone Settings
5.6.1 Call Control Settings
FIRSTDIGIT_TIM
Value Format Integer
Description Specifies the length of time, in seconds, within which the first digits of
a dial number must be dialed. When this timer expires, the unit will play
a busy tone.
Value Range 1–600
Default Value 30
INTDIGIT_TIM
Value Format Integer
Description Specifies the length of time, in seconds, within which subsequent digits
of a dial number must be dialed. When this timer expires after the last
key was pressed, dialing will start.
Value Range 1–15
Default Value 5
Web User Interface Reference Inter-digit Timeout (Page 140)
MACRODIGIT_TIM
Value Format Integer
288 Administrator Guide Document Version 2015-01
5.6.1 Call Control Settings