Loading...
Value Range 6–16 characters (except ", &, ', :, <, >, and space)
Note
This value must be the same as the value entered in [New
Password].
Default Value Not stored.
Configuration File Reference USER_PASS (Page 245)
4.4.4 Web Server Settings
This screen allows you to change the Web server settings.
4.4.4.1 Web Server Settings
Web Server Port
Description Specifies the port number used by the Web server.
Value Range 80, 1024–49151
Note
You cannot specify here the same port number as any of the
port numbers specified for the individual lines in [Source
Port] in 4.5.1.6 SIP Source Port.
Default Value 80
Note
When you change the default value of the port number to a
value other than "80", such as "8080", enter the URL for
accessing the Web user interface using the following format:
"http://192.168.0.100:8080/"
(192.168.0.100: IP address of the unit)
116 Administrator Guide Document Version 2015-01