Default Value 0
BUSY_TONE_RPT
Value Format Boolean
Description Specifies whether the busy tone is repeated.
Value Range
Y/Yes (Repeat)
N/No (No Repeat)
Default Value
Y
BUSY_TONE_TIMING
Value Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of busy tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range 0–16000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
Default Value 60,500,440
Web User Interface Reference Tone Timings (Page 159)
RINGBACK_TONE_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of ringback tones using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 440,480
Web User Interface Reference Tone Frequencies (Page 160)
RINGBACK_TONE_GAIN
Value Format Integer
Description Specifies the gain, in decibels, of the ringback tone.
Value Range (-80)–0
304 Administrator Guide Document Version 2015-01