Loading...
SIP_TIMER_T2
Value Format Integer
Description Specifies the maximum interval, in seconds, between transmissions of
SIP messages. For details, refer to RFC 3261.
Value Range
2
4
8
16
32
Default Value 4
Web User Interface Reference T2 Timer (Page 128)
SIP_TIMER_T4
Value Format Integer
Description Specifies the maximum period, in seconds, that a message can remain
on the network.
Value Range
0
1
2
3
4
5
Default Value 0
SIP_FOVR_NORSP
Value Format Boolean
Description Specifies whether to perform the fail-over process when the unit detects
that the SIP server is not replying to SIP message.
Value Range
Y/Yes (Enable fail-over)
N/No (Disable fail-over)
Note
If set to "Y", the unit will try to use the other SIP servers via the
DNS SRV and A records.
If set to "N", the unit will not try to use the other SIP servers.
Default Value
Y